NEXANS Cable Essential-6 U/UTP AWG24 Cat 6 LSZH Orange, Rola

Add To Wishlist Compare Compare
SKU: N100.161-OE Category:

Description

  • Unshielded construction
  • Complies to latest Category 6 standards
  • Central cross maintains geometry and performance
  • Supports Class E applications up to 250 MHz.

Standards

International :  ISO/IEC 11801
National :  ANSI/TIA-568-C.2
Declaration of Performance :  Reaction to fire: Dca-s2,d2,a2
according to EN50575:2014+A1:2016

 

Application

The Nexans Essential-6 cables are manufactured and tested to the latest Category 6 specifications. They are compatible with the complete Essential-6 modular and PCB connectivity range. When the cable is installed in conjunction with Essential-6 outlets and patch panels, a 25 year Class E Link Certificate can be obtained from the Nexans website.

Design

The Essential-6 cables have 24 AWG solid copper wires and comply with IEC 60228. The PE central cross filler keeps the pairs in place and reduces the risks of losing performance when bending the cable.
The cables are available with a Light Grey PVC or an Orange LSZH outer jacket.

Performance

Nexans Essential-6 cables are compliant with the requirements of the International, European and American cable standards, including ISO/IEC 11801, IEC 61156-5, EN 50173, EN 50288 and TIA/EIA 568-C.2.

Installation

The Essential-6 cables are as easy to install as their Category 5e equivalent, due to their small nominal outer diameter.

To support the correct set-up of hand held analysers for installation testing, the actual cable NVP value is given in the cable’s print legend.

Construction characteristics
Type of cable U/UTP
Outer sheath LSZH
Colour Orange
Dimensional characteristics
Diameter over insulation 0.94mm
Conductor cross-section (AWG) 24
Nominal outer diameter 5.7mm
Approximate weight 35kg/km
Electrical characteristics
Characteristic impedance 100Ohm
Transmission characteristics
Attenuation Crosstalk Ratio, 250MHz 5.5dB/100m
Nominal Velocity of Propagation (NVP) 69%
Propagation delay, max. 100 MHz 536ns/100m
Skew 30ns/100m
Usage characteristics
Category Cat. 6
Range essential-6
Minimum Bend Radius – During Installation (under Tension) 46mm
Minimum Bend Radius – Installed 23mm
Ambient installation temperature, range -10 .. 60°C
Operating temperature, range -20 .. 60°C
Flame retardant IEC 60332-1
Smoke density IEC 61034
Gases toxicity IEC 60754
Gases corrosivity IEC 60754
Packaging Box 305m
Field of application Indoor

Additional information

Coating

CO-Cable-Type

Producator

Garantie

Reviews

There are no reviews yet.